Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 3.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925 (chem.)
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 13.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
109 kg
0
220 211 - 108.632
13-000
bars-3m
ground
h-6-en
11.000
46713011000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod. UNS S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 11.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod.
UNS S42000 and UNS S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 6.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
as per AISI 420 mod. ESR remelted
as per ASTM F-899 and NF S94-090
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 4.50 mm, tolerance ISO h6
bars 3m
ground
h 6
593 kg
0
130 410 - 17.750|131 118 - 575.300
4-500
bars-3m
ground
h-6-en
5.000
46713005000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp.as per AMS 5925
and UNS S42025 (chem. only)
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl.4
diam. 5.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S 94-090
as per AISI 420 mod.
UNS S42025, UNS S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel
Reach/RoHS conforme
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 8.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 3.50 mm, tolerance ISO h6
bars 3m
ground
h 6
602 kg
0
250 811 - 237.928|280 812 - 364.000
3-500
bars-3m
ground
h-6-en
7.500
46713007500
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 7.50 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
854 kg
0
180 723 - 854.000
7-500
bars-3m
ground
h-6-en
4.000
46713004000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
as per ASTM F-899 and NF S94-090
as per AISI 420 mod., UNS S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel
cold worked, annealed, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 4.00 mm (0.1574″), ISO h6
bars 3m
ground
h 6
452 kg
800
291 116 - 343.050|260 918 - 108.550
4-000
bars-3m
ground
h-6-en
4.650
46713004650
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
Type 420 mod. UNS S42000
Analyse: AMS 5925 UNS S42025
as per ASTM F-899, NF S94 090
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 4.65 mm, tolerance ISO h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
Type 420 mod. UNS S42000
Analyse: AMS 5925, UNSS42025
nach ASTM F-899, NF S 94 090
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 12.00 mm, tolerance ISO 286-2/h6
Chronifer M-15 KL
W-Nr. 1.4123, X40CrMoVN16.2
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
AISI 420 mod., ASTM F-899,
NF S94 090, UNS S42025
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 24.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod., ESR remelted
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 7.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
AISI 420 mod., UNS S42000
nach ASTM F-899-20, NF S94 090
Chem. Analyse: AMS 5925 Rev. A, UNS S42025
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 10.00 mm, tolerance ISO h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
diam. 2.00 mm, tolerance ISO h6
bars 3m
ground
h 6
228 kg
0
310 310 - 228.422
2-000
bars-3m
ground
h-6-en
3.100
46713003100
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
Type 420 mod. UNS S42000, ASTM F-899
chem.: NF S94 090 + AMS 5925 + UNS S42025
hardenable stainless high end medical steel
annealed, ground, polished
in 3m bars (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested class 4
diam. 3.10 mm, tolerance ISO h6
bars 3m
ground
h 6
706 kg
0
200 218 - 706.300
3-100
bars-3m
ground
h-6-en
9.000
46713009000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
gemäss UNS S42025 und S42000
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 9.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1367 kg
0
170 112 - 573.800|180 723 - 793.000
9-000
bars-3m
ground
h-6-en
15.000
46713015000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per AISI 420 mod. UNS S42025
as per ASTM F-899 and NF S94-090
chemical .comp.as per AMS 5925
hardenable stainless medical steel, ESR
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 15.00 mm, tolerance ISO h6
bars 3m
ground
h 6
792 kg
0
030 912 - 167.700|231 019 - 624.000
15-000
bars-3m
ground
h-6-en
20.000
46713020000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S 94-090 (chem.)
as per AISI 420 mod. UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 20.00 mm, tolerance ISO h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 25.00 mm, tolerance ISO h6
bars 3m
ground
h 6
2014 kg
0
130 819 - 462.100|280 323 - 1552.000
25-000
bars-3m
ground
h-6-en
18.000
46713018000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl.4
diam. 18.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
1478 kg
0
111 209 - 3.000|290 823 - 1474.700
18-000
bars-3m
ground
h-6-en
6.350
46713006350
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
equivalent to X15TN, RoHS conforme
as per DIN EN 10088-3 12/14,
as per DIN EN 10277 09/18, Tab. 3
as per ASTM F-899 and NF S94-090 (chem.)
as per AISI 420 mod. ESR remelted
chemical .comp.as per AMS 5925
UNS S42000 and S42025
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 6.35 mm (1/4″), tolerance ISO 286-2/h6
bars 3m
ground
h 6
780 kg
0
161 023 - 484.000|171 023 - 296.000
6-350
bars-3m
ground
h-6-en
12.700
46713012700
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
equivalent to X15TN
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S 94-090
as per AISI 420 mod., UNS S42000
chemical .comp.as per AMS 5925 Rev. A
RoHs conforme
hardenable stainless medical steel
ESR remelted,annealed, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 12.70 mm (1/2″), tolerance ISO 286-2/h6
bars 3m
ground
h 6
1376 kg
1600
040 723 - 524.400|311 023 - 852.000
12-700
bars-3m
ground
h-6-en
40.000
46713040000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod., UNS S42025 (chem.only)
chemical .comp.as per AMS 5925 Rev. A
hardenable stainless medical steel, RoHS conform
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 40.00 mm, tolerance ISO h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp. AMS 5925, UNS S42025
RoHs, Reach conform
hardenable stainless medical steel, RoHS conform
annealed, ground, polished
in bars of 3m lengths (+40/0mm)
ultrasonic tested,
100% eddycurrent crack tested
diam. 50.00 mm, tolerance ISO h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod. UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
ultrasonic inspected per EN 10308, Tab. 1
diam. 14.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
1039 kg
0
290 622 - 379.400|171 023 - 660.000
14-000
bars-3m
ground
h-6-en
26.000
46713026000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 26.00 mm, tolerance ISO h6
bars 3m
ground
h 6
448 kg
0
111 109 - 447.900
26-000
bars-3m
ground
h-6-en
30.000
46713030000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp. AMS 5925
UNS S42025 (chem.only)
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
ultrasonic inspected
diam. 30.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000
chem.comp. per AMS 5925, UNS S42025
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 27.00 mm, tolerance ISO h6
bars 3m
ground
h 6
706 kg
0
260 612 - 706.100
27-000
bars-3m
ground
h-6-en
22.000
46713022000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94 090 (chem.)
as per AISI 420 mod.
UNS S42025 und UNS S42000
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 22.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
591 kg
2400
170 919 - 37.400|120 624 - 1053.600
22-000
bars-3m
ground
h-6-en
5.500
46713005500
Chronifer M 15 KL
W-Nr. 1.4123 ESU Rev. 4 2022-09,
ASTM F-899-23, X40CrMoVN16.2
SAE-AMS 5925 Rev. B 04/18
UNS S42025 (nur chem. Analyse)
gemäss DIN EN 10088-3
AISI420, UNS S42000, NF S94 090 2005-11
chemical .comp.as per AMS 5925 Rev. A
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 5.50 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
780 kg
0
130 612 - 1.200|270 922 - 778.300
5-500
bars-3m
ground
h-6-en
23.500
46713023500
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42025, S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel
peeled, annealed, ground, polished
in bars of 3m lengths (+50/0mm)
chamfered at both ends,
100% eddycurrent crack tested
diam. 23.5 mm, tolerance ISO h6
bars 3m
ground
h 6
75 kg
0
270 110 - 74.900
23-500
bars-3m
ground
h-6-en
2.500
46713002500
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
diam. 2.50 mm, tolerance ISO h6
bars 3m
ground
h 6
433 kg
0
170 310 - 89.999|080 512 - 343.500
2-500
bars-3m
ground
h-6-en
17.000
46713017000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod., UNS S42025, S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
ultrasonic tested per DIN 10308-1
100% eddycurrent crack tested cl. 4
diam. 17.00 mm, tolerance ISO 286-2/h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod. ESR remelted
chemical .comp.as per AMS 5925
per TST N 051 12.20 (chem.Analyse)
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 6.50 mm, tolerance ISO h6
bars 3m
ground
h 6
699 kg
0
050 411 - 66.100|240 117 - 632.600
6-500
bars-3m
ground
h-6-en
21.000
46713021000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 21.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1004 kg
0
230 211 - 216.100|090 320 - 788.000
21-000
bars-3m
ground
h-6-en
28.000
46713028000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 28.00 mm, tolerance ISO h6
bars 3m
ground
h 6
293 kg
0
140 211 - 287.600|160 211 - 5.200
28-000
bars-3m
ground
h-6-en
35.000
46713035000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 35.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1417 kg
0
251 114 - 57.208|160 523 - 1360.000
35-000
bars-3m
ground
h-6-en
60.000
46713060000
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoVN16.2
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod., RoHS, Reach conform
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
100% eddycurrent crack tested cl. 4
ultrasonic inspected
diam. 60.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
2668 kg
0
221 122 - 956.000|130 224 - 1712.000
60-000
bars-3m
ground
h-6-en
8.500
46713008500
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
AISI 420 mod. UNS S42025
Analyse: AMS 5925 Rev. A, UNS S42000
ASTM F-899-20, NF S94 090,
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 8.50 mm, tolerance ISO h6
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoVN16.2
as per ASTM F-899 and NF S94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
100% eddycurrent crack tested
diam. 60.00 mm, tolerance ISO 286-2/h9
bars 3m
ground
h 9
195 kg
0
110 719 - 194.800
60-000
bars-3m
ground
h-9-en
38.000
46713038000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000, UNS S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 38.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1539 kg
0
211 211 - 85.800|070 824 - 1453.000
38-000
bars-3m
ground
h-6-en
1.650
46700701650
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoNV 16-2
as per DIN EN 10088-3
AISI 420 mod., Analyse: AMS 5925
as per ASTM F-899, NFS 94090
hardenable stainless medical steel
annealed, cold drawn, in coils
diam. 1.65 mm, tolerance ISO fg7
in spools
drawn
fg 7
172 kg
0
300 811 - 172.300
1-650
in-spools
drawn
fg-7-en
2.100
46700702100
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoNV 16-2
AISI 420 mod., Analyse: AMS 5925
as per ASTM F-899, NFS 94090
hardenable stainless medical steel
annealed, cold drawn, in coils
diam. 2.10mm, tolerance ISO fg7
in spools
drawn
fg 7
222 kg
0
130 911 - 221.600
2-100
in-spools
drawn
fg-7-en
1.800
46700701800
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoNV 16-2
AISI 420 mod., Analyse: AMS 5925
as per ASTM F-899, NFS 94090
hardenable stainless medical steel
annealed, cold drawn, in coils
diam. 1.80 mm, tolerance ISO fg7
in spools
drawn
fg 7
230 kg
0
060 911 - 230.000
1-800
in-spools
drawn
fg-7-en
75.000
46711475000
Chronifer M 15 KL
mat.no 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14
AISI 420 mod., UNS S42000
Analyse: AMS 5925B 04/18, UNS S42025
as per ASTM F-899-20, NF S94 090
hardenable stainless medical steel
annealed, peeled surface
in bars of 2m lengths (+/-50 mm)
crack proofed as per DIN/EN/ISO 9443 Kl. C
ultrasonic inspected per DIN
EN 10308 Teb.1, Typ1a
round 75.00mm, tolerance ISO h11 (ISO 286-2)
Chronifer M 15 KL
mat.no 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14
AISI 420 mod., UNS S42000
chem. Analyse: AMS 5925B 04/18, UNS S42025
as per ASTM F-899-20, NF S94 090
hardenable stainless medical steel
annealed, peeled surface
in bars of 2m lengths (+/-50 mm)
crack proofed as per DIN/EN/ISO 9443 Kl. C
ultrasonic inspected per DIN
EN 10308 Teb.1, Typ1a
round 90.00mm, tolerance ISO h11 (ISO 286-2)
Chronifer M 15 KL
mat.no 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14
AISI 420 mod., UNS S42000
Analyse: AMS 5925B 04/18, UNS S42025
as per ASTM F-899-20, NF S94 090
hardenable stainless medical steel
annealed, peeled surface
in bars of 3m lengths (+/-50 mm)
crack proofed as per DIN/EN/ISO 9443 Kl. C
ultrasonic inspected per DIN
EN 10308 Teb.1, Typ1a
round 105mm, tolerance ISO h11 (ISO 286-2)
special length
ground
h 11
3232 kg
0
160 124 - 1616.000|150 124 - 1616.000
105-000
special-length
ground
h-11-en-2
32.000
46713032000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 32.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1543 kg
0
241 114 - 616.900|200 224 - 926.000
32-000
bars-3m
ground
h-6-en
45.000
46713045000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per AISI 420 mod.
chemical .comp.as per AMS 5925
as per ASTM F-899-20, NF S94-090,
UNS S42000, UNS S42025 (chem.)
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 45.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
730 kg
1000
050 116 - 29.700|211 221 - 700.300
45-000
bars-3m
ground
h-6-en
9.520
46713009520
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
equivalent to X15TN
as per DIN EN 10088-3, ESR remelted
Type 420 mod., UNS 42000,ASTM F-899
Analyse: NF S94 090, AMS 5925,UNS S42025
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 9.52 mm (3/8″), tolerance ISO h6
bars 3m
ground
h 6
672 kg
0
280 420 - 671.500
9-520
bars-3m
ground
h-6-en
25.400
46713025400
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 25.40mm (1″), tolerance ISO h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod., UNS S42000, S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 29.00 mm, tolerance ISO h6
bars 3m
ground
h 6
695 kg
0
210 812 - 357.000|161 012 - 338.000
29-000
bars-3m
ground
h-6-en
3.150
46713003150
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
as per ASTM F-899 and NF S 94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 3.15 mm, tolerance ISO h6
bars 3m
ground
h 6
401 kg
0
170 117 - 14.866|280 223 - 386.500
3-150
bars-3m
ground
h-6-en
42.000
46713042000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per AISI 420 mod. UNS S42000
chemical .comp.as per AMS 5925
ASTM F-899, NF S94-090, UNS S42025
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: chamfered at both ends
100% eddycurrent crack tested
diam. 42.00 mm, tolerance ISO h6
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3
Type 420 mod. UNS S42000
Analyse: AMS 5925 UNS S42025
as per ASTM F-899, NF S94 090
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 4.76mm 0.1875” (3/16″), tolerance ISO h6
bars 3m
ground
h 6
492 kg
0
261 015 - 134.000|271 015 - 358.000
4-760
bars-3m
ground
h-6-en
23.000
46713023000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S 94-090 (chem.only)
as per AISI 420 mod. UNS S42025, UNS S42000
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 23.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1176 kg
0
100 118 - 1176.300
23-000
bars-3m
ground
h-6-en
1.800
46702101800
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoNV 16-2
AISI 420 mod., Analyse: AMS 5925
as per ASTM F-899, NFS 94090
hardenable stainless medical steel
anneald, drawn, in 2m bars (+30/0mm)
diam. 1.80 mm, tolerance ISO h7
bars 2m
drawn
h 7
10 kg
0
060 911 - 10.000
1-800
bars-2m
drawn
h-7-en
43.000
46713043000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per AISI 420 mod. UNS S42000
chemical .comp.as per AMS 5925
as per ASTM F-899, NF S 94-090, UNS S42025
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 43.00 mm, tolerance ISO h6
bars 3m
ground
h 6
538 kg
0
230 518 - 538.000
43-000
bars-3m
ground
h-6-en
55.000
46713055000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod.,Analyse: AMS 5925
UNS S42000, UNS S42025
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: chamfered
100% eddycurrent crack tested cl. 4
diam. 55.00 mm, tolerance ISO h6
bars 3m
ground
h 6
828 kg
0
290 424 - 828.000
55-000
bars-3m
ground
h-6-en
3.100
46700703100
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoNV 16-2
DIN EN 10088-3 12/14
AISI 420 mod. ASTM F-899, NF S94 090
hardenable stainless medical steel
annealed, cold drawn, in coils
diam. 3.10mm, tolerance ISO fg7
in spools
drawn
fg 7
218 kg
0
250 919 - 218.000
3-100
in-spools
drawn
fg-7-en
6.000
46713906000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899 and NF S94-090
as per AISI 420 mod. UNS S42000 and
UNS S42025
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested
diam. 6.00 mm, tolerance ISO h5
bars 3m
ground
h 5
236 kg
0
310 120 - 236.300
6-000
bars-3m
ground
h-5-en
10.000
467130100001
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
AISI 420 mod., ASTM F-899, NF S94 090
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
Swissline (AMS-STD 2154A/AMS2632A)
diam. 10.00 mm, tolerance ISO h6
bars 3m
ground
h 6
325 kg
0
190 619 - 324.500
10-000
bars-3m
ground
h-6-en
24.000
467130240001
Chronifer M-15 KL
W-Nr. 1.4123, X40CrMoVN16.2
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
AISI 420 mod., ASTM F-899,
NF S94 090,UNS S42025
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 24.00 mm, tolerance ISO h6
bars 3m
ground
h 6
4 kg
0
220 207 - 3.500
24-000
bars-3m
ground
h-6-en
19.050
46713019050
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per ASTM F-899-20, NF S 94-090 (chem.)
as per AISI 420 mod. UNS S42000,
UNS S42025 (chem. only)
chemical .comp.as per AMS 5925 Rev. A 08/06
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
ultrasonic inspected per DIN EN 10308 Tab.1
diam. 19.05 mm (3/4”), tolerance ISO h6
bars 3m
ground
h 6
304 kg
1600
110 521 - 304.100
19-050
bars-3m
ground
h-6-en
85.000
46711485000
Chronifer M 15 KL
mat.no 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14
AISI 420 mod., UNS S42000
Analyse: AMS 5925B 04/18, UNS S42025
as per ASTM F-899-20, NF S94 090
hardenable stainless medical steel (not certified for aeronautical purposes9
annealed, peeled surface
in bars of 2m lengths (+/-50 mm)
crack proofed as per DIN/EN/ISO 9443 Kl. C
ultrasonic inspected per DIN
EN 10308 Teb.1, Type 1a
round 85.00mm, tolerance ISO 286-2/h11
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoVN16.2
as per ASTM F-899-20, NF S94-090 (chem.)
as per AISI 420 mod. UNS S42025/S42000
as per AMS 5925 Rev. B (chem. only)
hardenable stainless medical steel
(not certified for aeronautical purposes)
annealed, peeled surface
hardness: < 265 HB, ultrasonic inspected as per DIN EN 10308 Tab. 1, Typ 1a, Tab. 2, cl. 4
eddycurrent crack inspected per ISO 9443,cl.C
in bars of 2m lengths (+/-50 mm)
diam. 65.00 mm, tolerance ISO 286-2/h11
special length
ground
h 11
0 kg
0
0
65-000
special-length
ground
h-11-en-2
80.000
46711480000
Chronifer M 15 KL
mat.no 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14
AISI 420 mod., UNS S42000
Analyse: AMS 5925B 04/18, UNS S42025
as per ASTM F-899-20, NF S94 090
hardenable stainless medical steel
annealed, peeled surface
in bars of 2m lengths (+/-50 mm)
crack proofed as per DIN/EN/ISO 9443 Kl. C
ultrasonic inspected per DIN
EN 10308 Teb.1, Typ1a
round 80.00mm, tolerance ISO h11 (ISO 286-2)
special length
ground
h 11
2787 kg
0
140 921 - 1527.100|251 023 - 1260.000
80-000
special-length
ground
h-11-en-2
70.000
46711470000
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoVN16.2
as per ASTM F-899-20, NF S94-090 (chem.)
as per AISI 420 mod. UNS S42025/S42000
as per AMS 5925 Rev. B (chem. only)
hardenable stainless medical steel
annealed, peeled surface
hardness: < 265 HB, ultrasonic inspected as per DIN EN 10308 Tab. 1, Typ 1a, Tab. 2, cl. 4
eddycurrent crack inspected per ISO 9443,cl.C
in bars of 2m lengths (+/-50 mm)
diam. 70.00 mm, tolerance ISO h11 (ISO 286-2)
special length
ground
h 11
1975 kg
0
140 921 - 1046.600|060 224 - 928.000
70-000
special-length
ground
h-11-en-2
47.000
46713047000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per AISI 420 mod.UNS S42025 (chem.)
chemical .comp.as per AMS 5925 Rev.A
as per ASTM F-899-20, NF S94-090,
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
100% eddycurrent crack tested cl. 4
ultrasonic tested
diam. 47.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
1130 kg
0
110 122 - 1130.000
47-000
bars-3m
ground
h-6-en
33.000
46713033000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per ASTM F-899-20, NF S 94-090 (chem.)
as per AISI 420 mod. UNS S42000,
UNS S42025 (chem. only)
chemical .comp.as per AMS 5925 Rev. A 08/06
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: chamfered both ends
100% eddycurrent crack tested cl. 4
ultrasonic inspected per DIN EN 10308 Tab.1
diam. 33.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
1017 kg
0
031 122 - 1016.800
33-000
bars-3m
ground
h-6-en
34.000
46713034000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per ASTM F-899-20, NF S 94-090 (chem.)
as per AISI 420 mod. UNS S42000,
UNS S42025 (chem. only)
chemical .comp.as per AMS 5925 Rev. A 08/06
hardenable stainless medical steel
annealed, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: chamfered both ends
100% eddycurrent crack tested cl. 4
ultrasonic inspected per DIN EN 10308 Tab.1
diam. 34.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
592 kg
0
210 622 - 592.000
34-000
bars-3m
ground
h-6-en
3.300
46713003300
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per EN 10088-3 12/14
AISI 420 mod., Analyse: SAE-AMS 5925 Rev. B
as per ASTM F-899-20, NF S94 090
UNS S42000, UNS S42025 (chem only)
chemical .comp.as per AMS 5925
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 3.30 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
526 kg
0
061 222 - 272.000|051 222 - 254.000
3-300
bars-3m
ground
h-6-en
31.750
46713031750
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod., UNS S42025, S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel, RoHS conforme
annealed, drawn, ground, polished
in bars of 3m lengths (+40/0mm)
end of bars: pointed, chamfered
ultrasonic tested per DIN 10308-1
100% eddycurrent crack tested cl. 4
diam. 31.75 mm (1 1/4”), tolerance ISO h6
bars 3m
ground
h 6
704 kg
0
200 224 - 221.200|160 424 - 483.000
31-750
bars-3m
ground
h-6-en
57.000
46713057000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp. AMS 5925, UNS S42025
RoHs, Reach conform
hardenable stainless medical steel, RoHS conform
annealed, ground, polished
in bars of 3m lengths (+40/0mm)
ultrasonic tested,
100% eddycurrent crack tested
diam. 57.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1452 kg
0
051 223 - 1452.300
57-000
bars-3m
ground
h-6-en
52.000
46713052000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp. AMS 5925, UNS S42025 (chem.)
RoHs, Reach conform
hardenable stainless medical steel, RoHS conform
annealed, ground, polished
in bars of 3m lengths (+40/0mm)
ultrasonic tested,
100% eddycurrent crack tested
diam. 52.00 mm, tolerance ISO h6
bars 3m
ground
h 6
1625 kg
0
051 223 - 1625.000
52-000
bars-3m
ground
h-6-en
65.000
46733465000
Chronifer M 15 KL
W-Nr. 1.4123, X40CrMoVN16.2
as per ASTM F-899-20, NF S94-090 (chem.)
as per AISI 420 mod. UNS S42025/S42000
as per AMS 5925 Rev. B (chem. only)
hardenable stainless medical steel
(not certified for aeronautical purposes)
annealed, peeled surface
hardness: < 265 HB, ultrasonic inspected as per DIN EN 10308 Tab. 1, Typ 1a, Tab. 2, cl. 4
eddycurrent crack inspected per ISO 9443,cl.C
in bars of 3m lengths (+/-50 mm)
diam. 65.00 mm, tolerance ISO 286-2/h11
bars 3m
scaled
h 11
1353 kg
0
070 323 - 1352.500
65-000
bars-3m
scaled
h-11-en-2
63.500
46733463500
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per AISI 420 mod.UNS S42025 (chem.)
chemical .comp.as per AMS 5925 Rev.A
as per ASTM F-899-20, NF S94-090,
hardenable stainless medical steel
rolled, annealed execution
in bars of 3m lengths (+50/0mm)
100% ultrasonic inspected
diam. 63.50 mm (2.5”), tolerance ISO 286-2/h11
bars 3m
scaled
h 11
1560 kg
0
070 323 - 1560.000
63-500
bars-3m
scaled
h-11-en-2
13.000
46713113000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod.
chemical .comp.as per AMS 5925 (chem.)
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
ultrasonic inspected per EN 10308, Tab.1, Typ 1a
diam. 13.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 7
704 kg
0
180 723 - 704.000
13-000
bars-3m
ground
h-7-en
7.930
46713007930
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod.
UNS S42025, UNS S42000
chemical .comp.as per AMS 5925
hardenable stainless medical steel
Reach/RoHS conforme
annealed, drawn, ground, polished
in bars of 3m lengths (+30/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 7.93 mm (5/16”), tolerance ISO 286-2/h6
bars 3m
ground
h 6
881 kg
0
211 123 - 881.000
7-930
bars-3m
ground
h-6-en
38.100
46713038100
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp. AMS 5925
UNS S42025 (chem.only)
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
ultrasonic inspected
diam. 38.1 mm (1 1/2”), tolerance ISO 286-2/h6
bars 3m
ground
h 6
1329 kg
0
291 024 - 1329.000
38-100
bars-3m
ground
h-6-en
37.000
46713037000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod. UNS S42000
chemical .comp. AMS 5925
UNS S42025 (chem.only)
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
ultrasonic inspected
diam. 37.00 mm, tolerance ISO 286-2/h6
bars 3m
ground
h 6
1377 kg
0
011 024 - 1377.000
37-000
bars-3m
ground
h-6-en
20.000
46731820000
Brief description
Designation Klein:
CHRONIFER M-15 KL
Class of metals:
Hardenable martensitic stainless steel
with N and V additions
Material number:
1.4123
Standard EN:
X 40 CrMoVN 16-2
Remelting:
ESR
Machinability:
up to satisfactory
Hardening capability:
up to 58 HRc
Polishing ability:
adapted for mirror polishing
Corrosion resistance:
satisfactory up to good in the hardened,
polished and passivized condition
Magnetism:
magnetic
Uses:
medical, surgical and dental
instruments
special length
scaled
spec.
8 kg
0
010 207 - 7.700
20-000
special-length
scaled
spec-en
16.000
46713016000
Chronifer M 15 KL
German no. 1.4123, X40CrMoVN16.2
as per DIN EN 10088-3 12/14, ESR remelted
as per ASTM F-899-20 and NF S94-090
as per AISI 420 mod., RoHS conform
chemical .comp.as per AMS 5925
UNS S42025 and S42000 (chem.)
hardenable stainless medical steel
annealed, drawn, ground, polished
in bars of 3m lengths (+50/0mm)
end of bars: pointed, chamfered
100% eddycurrent crack tested cl. 4
diam. 16.00 mm, tolerance ISO 286-2/h6